- Porting pattern to DIN 24 340 form A,
- ISO 4401 and CETOP-RP 121 H
- Wet pin DC or AC solenoids with removable coil
- Solenoid coil can be rotated through 90¡ã
- It is not necessary to drain oil when the coil is replaced
- Fault override button, optional
- Waterproof pin plug, optional
- Large-scope suitable voltage, optional
Type WE valves are solenoid operated directional spool valves. They control the start, stop and direction of
flow.
The directional control valves consist of housing (1), one or two solenoids (2), the control spool (3), and one or
two return springs (4).
In the de-energised condition the control spool (3) is held in the neutral or initial position by means of return
springs (4) (except for impulse spools). The control spool (3) is actuated via wet pin solenoids (2).
To guarantee satisfactory operation care should be taken to ensure that the solenoid pressure chamber is filled
with oil.
The control spool(3) is moved to the expected position by solenoid(2) and pushing rod(5). This gives free-flow
from P to A and B to T or P to B and A to T.
When solenoid (2) is de-energised, the control spool (3) is returned to its initial position by means of the return
springs (4).
The solenoids may also control the control spool (3) by an optional override button(6) under the de-energised
condition.
Type 4WE 6.. L6X/O...(only possible for symbols A, C and D)
This version has 2 switched positions and 2 solenoids without detent.
Type 4WE 6.. L6X/OF... (impulse spool, only for symbols A, C and D)
This version has 2 switched positions, 2 solenoids and a detent. Both switched positions are thus fixed
alternately and so it is unnecessary to continually energise the solenoid.
Cartridge throttle (type 4WE 6..L6X/¡-/B.. )
The cartridge throttle is necessary since actual flow may be larger than the
performance limits of the valve during switching process.
This is inserted in the P channel of the directional control valve.
For application in voltage pulsation, solenoids with large scope voltage
are recommended.
For application in high protective grade, waterproof plug should be used.